Please use this identifier to cite or link to this item: http://imsear.hellis.org/handle/123456789/70475
Title: Ultrasonic measurements of extraocular muscle thickness in normal Indian population.
Authors: Arora, R
Verma, L
Kumar, A
Issue Date: 1-Oct-1990
Citation: Arora R, Verma L, Kumar A. Ultrasonic measurements of extraocular muscle thickness in normal Indian population. Indian Journal of Ophthalmology. 1990 Oct-Dec; 38(4): 164-5
Abstract: Standardized 'A' mode of Kretztechnik--7200 mA was used in 40 eyes of 20 patients for the measurement of extraocular muscle thickness. The mean thickness value of medial, lateral, superior and inferior rectus in the normal Indian population was found to be as 4.015 +/- 0.762 mm, 3.548 +/- 0.369 mm, 3.757 +/- 0.654 mm and 3.177 +/- 0.662 mm respectively.